Product Details:
Material Of Construction | Mild Steel |
Inlet Flow Rate(m3/day or m3/hr) | 100 m3/hr |
Air Blower Power | 0.4 KW |
Water Source | Commercial Waste Water |
Automation Grade | Automatic |
Product Capacity | 5MLD |
Product Details:
Plant Capacity | 2000 LPH |
Application Industry | Residential & Commercial Building |
Treatment Technology | Membrane Bioreactor(MBR) |
Water Pump Power | 1.5 KW |
Automation Grade | Automatic |
Air Blower Count | 1 Blower |
Product Details:
Plant Capacity | 5000 LPH |
Water Source Type | Industrial Effluent |
Automation Grade | Semi-Automatic |
Voltage | 240V |
Air Blower Power | 0.4 KW |
Power Source | Electric |
The 5000 LPH Water Treatment Plant process may vary slightly at different locations, depending on the technology of the plant and the water it needs to process, but the basic principles are largely the same. This section describes standard water treatment processes.
Below mentioned are the steps involved in the Water Treatment Plant Process.
1. Coagulation / FlocculationDuring coagulation, liquid aluminium sulfate (alum) and/or polymer is added to untreated (raw) water. When mixed with the water, this causes the tiny particles of dirt in the water to stick together or coagulate. Next, groups of dirt particles stick together to form larger, heavier particles called flocs which are easier to remove by settling or filtration.
2. SedimentationAs the water and the floc particles progress through the treatment process, they move into sedimentation basins where the water moves slowly, causing the heavy floc particles to settle to the bottom. Floc which collects on the bottom of the basin is called sludge, and is piped to drying lagoons. In Direct Filtration, the sedimentation step is not included, and the floc is removed by filtration only.
3. FiltrationWater flows through a filter designed to remove particles in the water. The filters are made of layers of sand and gravel, and in some cases, crushed anthracite. Filtration collects the suspended impurities in water and enhances the effectiveness of disinfection. The filters are routinely cleaned by backwashing.
4. DisinfectionWater is disinfected before it enters the distribution system to ensure that any disease-causing bacteria, viruses, and parasites are destroyed. Chlorine is used because it is a very effective disinfectant, and residual concentrations can be maintained to guard against possible biological contamination in the water distribution system.
5. Sludge DryingSolids that are collected and settled out of the water by sedimentation and filtration are removed to drying lagoons.
6. FluoridationWater fluoridation is the treatment of community water supplies for the purpose of adjusting the concentration of the free fluoride ion to the optimum level sufficient to reduce dental caries. Hunter Water is required to fluoridate water in accordance with the NSW Fluoridation of Public Water Supplies Act 1957.
7. pH CorrectionLime is added to the filtered water to adjust the pH and stabilise the naturally soft water in order to minimize corrosion in the distribution system, and within customers’ plumbing.
Product Details:
Material | Mild Steel (MS) |
Usage/Application | Water Purification |
Filter Type | Ultra Filtration |
Filter Medium Material | Microfiber |
Maximum Differential Pressure | 150psi (10bar) |
Voltage | 240V |
Product Details:
Type Of Aerator | Diffused Aerations |
Usage/Application | Aquaculture |
Treatment Technique | Clarifier |
Air Flow Rate | 5(m3/h) |
Type Of Bubble | Fine Bubble |
Bubble Diameter | 1 mm |
Color | Blue |
Product Details:
RO Capacity | 1000 LPH |
Material | Stainless Steel |
Automation Grade | Automatic |
RO Membrane Type | Thin-Flim Composite (TFC) |
Features | Filter Change Alarm |
Media | Activated Carbon + sand |
Purification Type | RO Only |
Usage/Application | Domestic |
Color | Blue |
The Domestic RO Plants Makes Water ,Both Chemically and microbiologically potable by Reducing Hardness, total Dissolved Solids (TDS) and Heavy metals Contaminants Like Arsentic,Mercury and Lead.It also Restores the Original taste and essential minerals.
Contamination |
Caused Disease |
RO |
UV |
Boiling |
Sodium |
Heart Disease |
Yes |
No |
No |
Calcium |
Kidney Stone |
Yes |
No |
No |
Magnesium |
Kidney stone |
Yes |
No |
No |
Lead |
Mental Retardation |
Yes |
No |
No |
Bacteria |
Bacterial Diseases |
Yes |
Yes |
Yes |
Virus |
Viral Disease |
Yes |
Yes |
Yes |
Fluoride |
Fluor sis |
Yes |
No |
No |
Arsenic |
Poisoning |
Yes |
No |
No |
Iron |
Constipation |
Yes |
No |
No |
Insecticides & Pesticides |
cancer |
Yes |
No |
No |
Bad Taste and Odour |
|
Yes |
No |
No |
Product Details:
Water Source Type | Commercial Waste Water |
Type | Horizontal Flow |
Treatment Capacity | 1000 m3/hr |
Bridge Width | 1.5 m |
Automation Grade | Automatic |
Usage/Application | Water Purification |
Material | Stainless Steel |
Voltage | 240V |
Product Details:
RO Capacity | 1500 ltr/hr |
Material | Stainless Steel |
Automation Grade | Semi-Automatic |
RO Membrane Type | Thin-Flim Composite (TFC) |
Media | Anthracite + Support Bed |
Usage/Application | Water Purification |
In the reverse osmosis process cellophane-like membranes separate purified water from contaminated water. RO is when a pressure is applied to the concentrated side of the membrane forcing purified water into the dilute side, the rejected impurities from the concentrated side being washed away in the reject water.
RO can also act as an ultra-filter removing particles such as some micro-organisms that may be too large to pass through the pores of the membrane.
Advantages of RO Water Purification:Product Details:
Capacity | 500 KLD |
Application Industry | Pharmaceutical & Chemicals |
Material Of Construction | Mild Steel |
Air Blower Power | 0.25 KW |
Water Source | Industrial Effluent |
Automation Grade | Automatic |
Product Details:
Water Source Type | Commercial Waste Water |
Type | Horizontal Flow |
Treatment Capacity | 500 m3/hr |
Automation Grade | Automatic |
Tank Diameter | 10 m |
Usage/Application | Water Purification |
Material | Stainless Steel |
Voltage | 240V |
Product Details:
Capacity (KLD/MLD) | 500 MLD |
Water Source Type | Industrial Wastewater |
AMC Provided | Yes |
Application Industry | Residential & Commercial Building |
Treatment Technology | Submerged Aerated Fixed Film Bioreactor(SAFF) |
Water Pump Power | 1 KW |
Automation Grade | Automatic |
Voltage | 240V |
Power Source | Electric |
500 MLD Sewage treatment Plants is the process of removing contaminants from wastewater, primarily from household sewage. It includes physical, chemical, and biological processes to remove these contaminants and produce environmentally safe treated wastewater (or treated effluent). A by-product of sewage treatment is usually a semi-solid waste or slurry, called sewage sludge, that has to undergo further treatment before being suitable for disposal or land application.
List of process types:
Product Details:
Installation Type | Prefabricated |
Material Of Construction | Stainless Steel |
Inlet Flow Rate(m3/day or m3/hr) | 500m3/hr |
Air Blower Power | 0.5 KW |
Treatment Technology | Membrane Bioreactor(MBR) |
Water Source | Commercial Waste Water |
Automation Grade | Automatic |